Process Chillers

aces – “where every problem has a solution”

Or you can visit our online shop to purchase click here

HVAC Service and Maintenance by ACES

Equipment Maintenance – What We Do. We can provide both air-conditioning and chiller service contracts tailored to your specific needs – from simple F-gas compliance to complex process cooling and critical plant maintenance. All Planned Preventative Maintenance quotations are supplied free of charge. Phone – 01865 890996 or email: service@acescomp.co.uk

Our Objective

Our aim is to increase the performance and efficiency of your equipment. We provide Planned Preventative Maintenance contracts usually based on two to four visits a year to ensure your HVAC equipment operates as efficiently as possible and to also reduce the risk of a breakdown, especially in the summer months! Our dedicated team of engineers will also ensure your business meets all the current environmental and legislative requirements. All of our engineers are fully trained in all aspects of the HVAC industry and have a wealth of experience and knowledge on most makes and models of air-conditioning and chiller plant equipment.

24/7 Service

ACES provide a 24/7 service throughout the year. Any repairs or maintenance to a breakdown in chiller or air-conditioning is only a phone call away. We operate a national 4 hour emergency call out.

Whether it’s major or minor, all repairs and works are completed at a time and budget to suit.

Key Benefits:

Supported Manufacturers + More
  • Keyter
  • Airedale
  • Carrier
  • York
  • Daikin
  • McQuay
  • Aermec
  • ICS Cool energy
  • Trane
  • Klima-Therm
  • Bluebox
  • Lennox
  • Turbocor
  • GEA Denco
  • Climaveneta
  • Hitachi
  • Mitsubishi
  • Samsung
  • LG
  • Hisense
  • Panasonic
  • Toshiba
  • Clivet
  • Rhoss
  • Liebert
  • Sanyo
  • Stulz
Expert Services
  • F-gas Compliance Maintenance
  • Chiller Maintenance
  • Chiller Repairs
  • Compressor Replacement
  • Controls Upgrades
  • Condenser Replacement
  • Expansion Valve Replacement
  • Condenser Fan EC Upgrades
  • Chiller Energy Management
  • Refrigerant Retrofits
  • Pressure Leak Testing – Oxygen Free Nitrogen
  • Refrigerant Leak Repair
  • Condenser Cleaning
  • Evaporator Replacement

Remember leak checks under F Gas changed on 1st January 2017

Mandatory documented leak checks apply to air conditioning and refrigeration equipment based on according to how much damage could be caused to the atmosphere if the whole charge were released.  The frequency of the test inspections is based on the GWP of the refrigerant multiplied by the estimated volume contained in each individual system – this gives the CO2e figure. If the system contains between:
5 and 50 tonnes CO2e it requires
50 to 500 tonnes CO2e it requires
Greater than 500 tonnes CO2e it requires
One inspection per year
Inspection every six months
Quarterly inspections
POA
POA
POA
Service ban that affects existing refrigeration equipment

In January 2020 there was a ban on using virgin HFCs to service refrigeration equipment that uses a refrigerant with a GWP above 2500. This mainly affects R-404A equipment, but is also relevant to plants using refrigerants such as R-507, R-434A and R-422D.

How to calculate F-gas GWP?

You calculate the carbon dioxide equivalent of a quantity of F gas by multiplying the mass of the gas (in tonnes), by the gas’ Global Warming Potential (GWP).