Water-Cooled Chillers
Or you can visit our online shop to purchase click here
Water Cooled Chiller Maintenance and Service Contracts
ACES can provide a service contract for your Water Cooled Chiller which can be tailored to your specific needs.
Whether you require bi-annual visits, quarterly visits or a ‘One Off’ maintenance solution. This can be essential if the equipment is changing hands or becoming the responsibility of a new tenant. Our engineers will provide the necessary documentation ensuring peace of mind for the transfer.
From simple F-gas compliance to complex process cooling and critical plant maintenance. All Planned Preventative Maintenance quotations are supplied free of charge. Phone – 01865 890996
What aces can do for you
Do you want to increase the performance and efficiency of your equipment?
We provide Planned Preventative Maintenance contracts usually based on two to four visits a year to ensure your Water Cooled Chiller equipment operates as efficiently as possible and will reduce the risk of breakdown, especially in the summer months!
Our dedicated team of engineers will also ensure your business meets all the current environmental and legislative requirements.
All our engineers are fully trained in all aspects of the HVAC industry and have gained a wealth of experience and knowledge on most makes and models of air-conditioning and chiller plant equipment.
We can provide, condenser cleaning, condenser replacement, evaporator replacement, expansion valve replacement, controls upgrade on Bluebox, Trane, Airedale, Lennox, Carrier, Aermec, Climaveneta, Turbocor, Hitachi, York and many more Chillers.
24/7 Service
ACES provide a 24/7 service throughout the year. Any repairs or maintenance to a breakdown in chiller or air-conditioning is only a phone call away. We operate a national 4 hour emergency call out.
Whether it’s major or minor, all repairs and works are completed at a time and budget to suit.
Key Benefits:
- Under 4 hour rapid response time nationally
- 2 Hours rapid response time in London area
- Manufacturer trained engineers
- Cost-effective service at a price to suit
- Remote monitoring & online services
- Joblogic service & online documentation
- Real-time tracking
- In-house unique compressor overhaul services (estimated 40% cheaper than competitors)
- In-house lifting services (estimated 40% cheaper than competitors)
- In-house pump & motor repairs
- Fully compliant service
- Generation to generation family business
- One point of call
Supported Manufacturers + More
- Keyter
- Airedale
- Carrier
- York
- Daikin
- McQuay
- Aermec
- ICS Cool energy
- Trane
- Klima-Therm
- Bluebox
- Lennox
- Turbocor
- GEA Denco
- Climaveneta
- Hitachi
- Mitsubishi
- Samsung
- LG
- Hisense
- Panasonic
- Toshiba
- Clivet
- Rhoss
- Liebert
- Sanyo
- Stulz
Expert Services
- F-gas Compliance Maintenance
- Chiller Maintenance
- Chiller Repairs
- Compressor Replacement
- Controls Upgrades
- Condenser Replacement
- Expansion Valve Replacement
- Condenser Fan EC Upgrades
- Chiller Energy Management
- Refrigerant Retrofits
- Pressure Leak Testing – Oxygen Free Nitrogen
- Refrigerant Leak Repair
- Condenser Cleaning
- Evaporator Replacement
Remember leak checks under F Gas changed on 1st January 2017
Mandatory documented leak checks apply to air conditioning and refrigeration equipment based on according to how much damage could be caused to the atmosphere if the whole charge were released. The frequency of the test inspections is based on the GWP (Global Warming Potential) of the refrigerant multiplied by the estimated volume contained in each individual system – this gives the CO2e figure. If the system contains between:
| 5 and 50 tonnes CO2e it requires |
| 50 to 500 tonnes CO2e it requires |
| Greater than 500 tonnes CO2e it requires |
| One inspection per year |
| Inspection every six months |
| Quarterly inspections |
| POA |
| POA |
| POA |
Service ban that affects existing refrigeration equipment
In January 2020 there was a ban on using virgin HFCs to service refrigeration equipment that uses a refrigerant with a GWP above 2500. This mainly affects R-404A equipment, but is also relevant to plants using refrigerants such as R-507, R-434A and R-422D.
How to calculate F-gas GWP?
You calculate the carbon dioxide equivalent of a quantity of F gas by multiplying the mass of the gas (in tonnes), by the gas’ Global Warming Potential (GWP).